HI 9828 |
|
pH |
0.00 to 14.00 pH
|
§Æ of pH input |
¡¾600.0 mV |
ORP |
¡¾2000.0 mV |
Dissolved Oxygen |
0.0 to 500.0% / 0.00 to 50.00 mg/L |
Conductivity |
0.000 to 200.000 mS/cm (actual EC up to 400
mS/cm) |
Resistivity |
0 to 999999 Ohm/cm; 0 to 1000.0 kOhm/cm; 0 to 1.0000 MOhm/cm
|
TDS |
0 to 400000 mg/L or ppm
(the maximum value depends on the TDS factor) |
Salinity |
0.00 to 70.00 PSU (extended Practical Salinity Scale) |
Seawater Specific
Gravity |
0.0 to 50.0 st, s0, s15 |
Atm. Pressure |
450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar;
8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Temp |
-5.00 to 55.00¡É; 23.00 to 131.00¢µ; 268.15 to 328.15K |
ÃÖ¼ÒÃøÁ¤´ÜÀ§ |
pH |
0.01 pH |
§Æ of pH input |
0.1 mV |
ORP |
0.1 mV |
Dissolved Oxygen |
0.1% / 0.01 mg/L |
Conductivity |
Manual: 1 ¥ìS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
Automatic: 1 ¥ìS/cm from 0 to 9999 ¥ìS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ;
0.1 mS/cm from 100.0 to 400.0 mS/cm Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
Resistivity |
Dependent on resistivity reading |
TDS |
Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt);
1 g/L (ppt) Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm);
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt);
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
|
Salinity |
0.01 PSU |
Seawater Specific
Gravity |
0.1 st, s0, s15 |
Atm. Pressure |
0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Temp |
0.01¡É; 0.01¢µ; 0.01K |
Á¤È®µµ |
pH |
¡¾0.02 pH |
§Æ of pH input |
¡¾0.5 mV |
ORP |
¡¾1.0 mV |
Dissolved Oxygen |
0.0 to 300.0%: ¡¾1.5% of reading or ¡¾1.0% whichever is greater;
300.0 to 500.0%: ¡¾3% of reading; 0.00 to 30.00 mg/L: ¡¾1.5% of reading or 0.10 mg/L
whichever is greater; 30.00 mg/L to 50.00 mg/L: ¡¾3% of reading |
Conductivity |
¡¾1% of reading or ¡¾1¥ìS/cm whichever is greater |
TDS |
¡¾1% of reading or ¡¾1mg/L |
Salinity |
¡¾2% of reading or 0.01 PSU whichever is greater |
Seawater Specific
Gravity |
¡¾1 st, s0, s15 |
Atm. Pressure |
¡¾2 mmHg within 15¡É from the temperature during calibration |
Temp |
¡¾0.15¡É; ¡¾0.27¢µ; ¡¾0.15K |
º¸Á¤
(Calibration) |
pH |
Automatic 1, 2, or 3 points with 5 memorized standard buffers
(pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer |
ORP |
Automatic at 1 custom point |
Conductivity |
Automatic 1 point with 6 memorized standards (84 ¥ìS/cm, 1413 ¥ìS/cm,
5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
Dissolved Oxygen |
Automatic 1 or 2 points at 0, 100% or 1 custom point |
Resistivity
TDS |
Based on conductivity or salinity calibration |
Atm. Pressure |
Automatic at 1 custom point |
Temp |
Automatic at 1 custom point |
Temperature Comrensation |
Automatic from -5 to 55¡É |
Logging ¸Þ¸ð¸® |
Up to 60000 samples with 13 measurements each
|
|
1 second to 3 hours
|
|
USB (with HI 92000 software)
|
|
Meter IP67, Probe IP68
|
|
0 to 50¡É; RH 100%
|
|
(4) 1.5V alkaline C cells (´ë·«. ¹è°æÁ¶¸í ¾øÀÌ 150 ½Ã°£)/
(4) 1.2V rechargeable C cells (¹è°æÁ¶¸í ¾øÀÌ ¾à. 70 ½Ã°£)
|
|
Meter: 221 x 115 x 55 mm; Probe: 270 x 46 mm DIA
Meter: 750g ; Probe: 750g
|