Á¦Ç°¸í:°¡¿¬¼º&CO2°¨Áö±â
¸ðµ¨¸í:GIR-3000

¢º ³»¾Ð¹æÆø ±¸Á¶·Î¼­ Æø¹ß À§ÇèÁö¿ª¿¡ ¼³Ä¡ÇÏ¿© °¡¿¬¼º, CO2, CO, N2O°¡½º¸¦ ¿¬¼ÓÀûÀ¸·Î °¨Áö
¢º ½Å±â¼úÀÇ Àû¿Ü¼±½Ä ÃøÁ¤¿ø¸® Àû¿ë
¢º ¾ÈÁ¤µÈ 5³â ÀÌ»óÀÇ ±ä¼ö¸í
¢º ¼³Ä¡ ÈÄ À¯Áöº¸¼ö°¡ ÇÊ¿äÇÏÁö ¾Ê¾Æ °ü¸®ºñ¿ë Àú·Å
¢º »ê¼Ò°¡ Á¸ÀçÇÏÁö ¾ÊÀº ȯ°æ¿¡¼­µµ »ç¿ë °¡´É
¢º ¸¶ÀÌÅ©·Î ÇÁ·Î¼¼¼­¸¦ Àû¿ëÇÑ ÀÚ±â Áø´Ü ±â´É ³»Àå
¢º 6ÃÊ À̳»ÀÇ ºü¸¥ ÀÀ´ä¼Óµµ
¢º Back-light¸¦ ³»ÀåÇÑ LCD or OLED Ç¥½Ã
¢º ¸¶±×³×ƽ ¹Ù¸¦ ÀÌ¿ë LCD or OLEDÇ¥½Ãâ°ú 1:1 ´ëÈ­ ¹æ½Ä¹æ½ÄÀÇ ¿ø°Ý ±³Á¤ ¹× ÇÁ·Î±×·¥ ¼³Á¤
¢º 2´Ü °æº¸¿Í 1°³ÀÇ °íÀåÇ¥½Ã ¹× ¸±·¹ÀÌ Á¢Á¡ Ãâ·Â
¢º 4-20mA DC Ãâ·Â½ÅÈ£
¢º RS-485 Modbus(isolated) Serial Åë½Å ¹× HART Åë½ÅÀ¸·Î ¸ð´ÏÅ͸µ ½Ã½ºÅÛ ±¸Ãà ¿ëÀÌ
¢º Alarm Beacon Type(Option, Model:GTL-100) GTL-100Á¦Ç°Àº °¨Áö±â¿Í ¿¬µ¿µÇ¾î µ¿ÀÛ
   GTL-100Á¦Ç°Àº °¨Áö±â¿Í ¿¬µ¿µÇ¾î µ¿ÀÛ
   -. Normal:ÃÊ·Ï»ö LED
   -. Alarm:»¡°£»ö LED, ºÎÀú µ¿ÀÛ(95dB)
   -. Trouble:³ë¶õ»ö LED
¢º ÀÛ¾÷ÀÚ 1ÀÎÀ¸·Î ±³Á¤ ¹× À¯Áöº¸¼ö

MODEL
GIR-3000
°¨Áö°¡½º

Hydrocarbon gases
(LNG, LPG, Methane, Buthane & etc

CO2
CO
N2O
°¨ÁöÇüÅÂ
´ë±âÈ®»ê½Ä (Diffusion type)
°¨Áö¹æ½Ä
Àû¿Ü¼±¹æ½Ä(Infrared type)
°¨Áö¹üÀ§
0-100%LEL 0-5,000ppm, 0-100%Vol
0-2.0%Vol
0-5.0%Vol
0-4000ppm
¼¾¼­¼ö¸í
Over 5 years
°¨Áö¼Óµµ
< 6sec / 90% scale, <3sec/50% scale
Á¤È®µµ
¡¾3%/Full scale
¼³Á¤Á¦¾î
¸¶±×³×Æ®(ÀÚ¼®)¿¡ ÀÇÇÑ ¿ø°ÝÁ¦¾î(±³Á¤, Á¡°Ë, Alarm¼³Á¤µî)
ÀÛµ¿Ç¥½Ã
4-LED(Power , 2-sate alarm, 1-trouble)
³óµµÇ¥½Ã
LCD Ç¥½Ã (Built-in back light 2-Line, 16 characters) / OLED Type(Option)
°æº¸Ãâ·Â
250V 1A/3-SPST Relay contact(2-stage alarm, 1-trouble)
Ãâ·Â½ÅÈ£
¾Æ³¯·Î±× Ãâ·Â
ÃøÁ¤Ãâ·Â : 4-20 mA DC
Á¡°ËÃâ·Â : 3 mA DC
±³Á¤Ãâ·Â  : 3 mA DC
°íÀåÃâ·Â : 0 mA DC
µðÁöÅÐ Ãâ·Â
: RS-485 Modbus(Option)
HART Communication(Option)
ÄÉÀ̺í/Àü¼Û°Å¸®
Àü¿ø+Àü·ùÄÉÀ̺í : 3 wire>1.5sq(AWG16) / 500m normal.
RS-485Åë½ÅÄÉÀ̺í : 1pair(UL2919 RS-485) / 1,000m max.
Àü¼±µµ°ü
G. Rc. NPT 1/2" & 3/4" & M20(G 3/4" standard)
¼³Ä¡¹æ½Ä
2" Pole mount, Wall mount, Duct mount
ÀÛµ¿¿Â.½Àµµ
-40 ¡É ~ +80¡É / 5 to 99% RH (Non-condensing)
Àü¿ø
18 ~ 31V DC (24V DC normal) / 400mA max.
Å©±â.¹«°Ô
156 x 319 x 110mm (W X H X D) / 3kg
½ÂÀÎ
Explosion proof type(Ex d ¥±C Gb T4,T6) ATEX, IECEx, CE, IP 66/67
Explosion proof type(Ex d ¥±C T6) KCs, NEPSI, CCCf
MED, KR, ABS, DNV, KFI, HART