Á¦Ç°¸í:ºÐÁøÃøÁ¤±â
¸ðµ¨¸í:TES-5200

¢º ºÐÁø ¹× ÆÄƼŬ »çÀÌÁî ÃøÁ¤
¢º 6°³ÀÇ ºÐÁø(mass) ¹üÀ§ : PM1, PM2.5, PM4, PM7, PM10, TSP
¢º 8°³ ÆÄƼŬ »çÀÌÁî ¹üÀ§ : 0.5§­, 0.7§­,1.0§­, 2.5§­, 4.0§­, 5.0§­, 7.0§­, 10.0§­
¢º ƯÁ¤ ÃøÁ¤ ȯ°æ¿¡¼­ »ç¿ëÀ» À§ÇÑ K-factors ¼³Á¤
¢º ¿Âµµ ¹× ½Àµµ ÅëÇÕ ¼¾¼­
¢º À¯·®(Flow rate) 2.83L/minute (0.1 CF / minute)
¢º ÃæÀü¹èÅ͸® ÃÖ´ë 4½Ã°£ »ç¿ë °¡´É (ÃæÀü:2.5½Ã°£-Fast Charge ¸ðµå)
¢º 500°³ ÃøÁ¤µ¥ÀÌÅÍ ÀúÀå
¢º SD Card ¸Þ¸ð¸®

¢º Àû¿ëºÐ¾ß
- HVAC Applications
- Controlled Environments
- Filter Testing
- Indoor Air Quality
- Mining & Ore Processing
- Hospitals & Clinics
- Emission Sourcing
- Monitoring Growning Rooms
MODEL
TES-5200
Operating principle ( ÃøÁ¤ ¿ø¸® )
Counts individual particles using scattered laser light and calculates
the equivalent mass concentration using a proper algorithm.
Optical system ( ±¤ÇÐ ½Ã½ºÅÛ )
Sideway light-scattering method
Light source ( ±¤¿ø )
Laser diode
Laser product class ( ·¹ÀÌÀú °ü·Ã ±Ô°Ý )
Class 1, IEC 60825-1 / EN 60825-1
Mass Mode ( ºÐÁø ÃøÁ¤ ¸ðµå )
Mass concentration ranges ( ºÐÁø ¹üÀ§ )
PM1, PM2.5, PM4, PM7, PM10, TSP
Concentration range ( ³óµµ ¹üÀ§ )
0~1000 ¥ì g/m©ø
Sample time ( »ùÇøµ ½Ã°£ )
1 minute (2.83 L/min)
Count Mode ( ÆÄƼŬ ÃøÁ¤ ¸ðµå )
Particle size ( ÆÄƼŬ »çÀÌÁî – 8 ä³Î )
0.5 §­ , 0.7 §­ ,1.0 §­ , 2.5 §­ , 4.0 §­ , 5.0 §­ , 7.0 §­ , 10.0 §­
Accuracy ( Á¤È®µµ )
¡¾10% to calibration aerosol
Sensitivity ( °¨µµ )
0.5 §­
Sample flow rate ( À¯·® )
2.83 L/min
Maximum particle concentration
( ÃÖ´ë ÆÄƼŬ ³óµµ )
105,900 particles / L (coincidence loss max. 5%)
Sample time ( »ùÇøµ ½Ã°£ )
6 s. (0.01CF), 21 s.(1 L), 1 min.(0.1CF,2.83L), 3 min.53s(10L),10 min. (1 CF,28.3L),
any length (MANUAL), any length (1s. to 59min. 59s.)
Relative Humidity ( »ó´ë ½Àµµ )
¡¾7%, 20% to 90% RH non-condensing
Temperature ( ¿Âµµ )
¡¾3 ¡É , 10 ¡É to 40 ¡É
Data storage ( µ¥ÀÌÅÍ ÀúÀå )
500 sample records (rotating buffer) in Mass mode
500 sample records (rotating buffer) in Count mode
Data recorded ( µ¥ÀÌÅÍ ÀúÀå Ç׸ñ )
Date, time, counts or mass, relative humidity,
temperature, sample volumes, alarms, label
Display ( µð½ºÇ÷¹ÀÌ )
TFT color display with backlightl
Interface ( ÀÎÅÍÆäÀ̽º )
USB
Dimension/Weight ( Å©±â / ¹«°Ô )
11.0 x 21.8 x 6.7 cm / 875g
Operating ( ÀÛµ¿ ¿Âµµ )
10 ¡ÆC to 40 ¡ÆC , 20 % to 90 % RH, non-condensing
Storage ( º¸°ü ¿Âµµ )
-10 ¡É to 50 ¡É , 0% to 90%RH, non-condensing
AC adapter ( ¾î´ðÅÍ )
12 VDC at 3A, 100 to 240V AC, 50/60 §Ô
Rechargeable Battery ( ÃæÀü ¹èÅ͸® )
Lithium ion, 8.4 V at 2.5 Ah; replaceable
Charge time ( ÃæÀü ½Ã°£ )
2 hours (Fast Charge mode)
27 hours (Trickle Charge mode)
Continuous Operating Time
( ÀÛµ¿ Áö¼Ó ½Ã°£ )
4 hours
Standards ( ±Ô°Ý )
Complies with CE, JIS B9921: 1997, ISO 21501-04
Accessories ( ±âº» ¾Ç¼¼»ç¸® )
Instruction manual, AC adapter, Power cord, USB Cable,
Zero count filter, Carrying case