[1]¼öÁúÃøÁ¤±â
[2]ȯ°æ.¸ÕÁö(ºÐÁø).°¡½º°ü·Ã±â±â
[3]±¼Àý°è(´çµµ.¿°µµ.»êµµ).Æí±¤°è
[4]¿Âµµ.¿Â½Àµµµ¥ÀÌÅͷΰÅ
[5]dz¼Ó.dz·® ±â»ó°ü·Ã±â±â
[6]°íµµ°è.±â¾Ð°è
[7]Ãʽðè.ŸÀ̸Ó
[8]¼ÒÀ½°è.Áøµ¿°è
[9]Á¡µµ.ȸÀü°è.½ºÆ®·Îº¸½ºÄÚÇÁ
[10]Á¶µµ¡¤»öÂ÷¡¤±¤ÅÃ,UV,À¯¸®Åõ°ú
[11]¼öºÐÃøÁ¤±â.¼öºÐÈ°¼ºµµÃøÁ¤±â
[12]Çö¹Ì°æ.È®´ë°æ.»ê¾÷¿ë³»½Ã°æ
[13]µÎ²².°æµµ.¾Ð·Â.À¶Á¡.Áø°ø.¹°¼º
[14]ÀüÀÚÀú¿ï.ÀüÀÚºñÁßÃøÁ¤±â
[15]Àü±â.ÀüÀÚ.Á¤Àü±â.°¡¿ì½º¸ÞŸ
[16]¹åµ¥¸®Å×½ºÅÍ
[17]Á¦¾à.³ó¾÷.½ÄÇ°°¡°ø.Çؾç±â±â
[18]PIPETTE(NICHIRYO)
[19]HANNA
[20]ISC°¡½ºÃøÁ¤±â
[21]LUTRON

 

Á¦Ç°»ó¼¼Á¤º¸
  ÇöÀçÀ§Ä¡ : > [19]HANNA > pH/EC/TDS/¡É Tester
Á¦Ç°»ó¼¼Á¤º¸ ÆäÀÌÁöÀÇ »ó´Ü ºÎºÐ¿¡ µé¾î°¥ ³»¿ëÀ» ÀÔ·ÂÇÏ´Â ºÎºÐ


Å«»çÁøº¸±â
Á¦Ç°¸í:pH/EC/TDS/¡É Tester
¸ðµ¨¸í:HI 98131

¢º 3°¡Áö Ç׸ñÀÇ ´ÜÀÏ ÃøÁ¤
¢º 0.00pH ~ 14.00pH ±îÁöÀÇ ³ÐÀº ¹üÀ§
¢º Stability indicator (ÃøÁ¤ ¼öÄ¡°¡ ¾ÈÁ¤ÀûÀÏ ¶§, ½Ã°è Ç¥½Ã°¡ È­¸é¿¡¼­ »ç¶óÁø´Ù.)
¢º ¼±Åà °¡´ÉÇÑ EC - TDS Àüȯ°è¼ö ¼³Á¤ -
   - 0.5 (500 CF) conversion factor = EC reading 1000 ¥ìS/cm = 500 ppm
   - 0.7 (700 CF) conversion factor = EC reading 1000 ¥ìS/cm = 700 ppm
¢º ÀÚµ¿ ¿Âµµ º¸»ó ±â´É ( Auto Temperature Compensation )
¢º Hold ±â´É°ú BEP ±â´É
¢º ¹èÅ͸® »óÅÂÇ¥½Ã ±â´É ¹× ÀÚµ¿ ²¨Áü( Auto-off ) ±â´É

HI 98131Àº ½½¸²ÇÏ°í, °¡º­¿î, ¹æ¼öÇü (»ýÈ°¹æ¼ö) Æ÷ÄÏ ¹ÌÅÍÀÔ´Ï´Ù.
pH, EC, TDS, ¿Âµµ ÃøÁ¤ÀÌ °¡´ÉÇÕ´Ï´Ù. 2°³ÀÇ ¹öÆ°À¸·Î ÀÛµ¿À» °£¼ÒÈ­½ÃÄ×½À´Ï´Ù.
On / OFF ¹öÆ°°ú ÃøÁ¤ ¸ðµå¸¦ º¯°æÇÏ´Â ¹öÆ°À¸·Î ±¸¼ºµÇ¾îÀÖÀ¸¸ç, EC¿Í TDS ÀÇ Àüȯ°è¼ö ( Conversion factor )
±â´ÉÀ» Çâ»ó½ÃÄ×½À´Ï´Ù. ( 0.5-500ppm / 0.7-700ppm )

One Button º¸Á¤
pH º¸Á¤ÀÌ 1 ȤÀº 2 point º¸Á¤ÀÌ °¡´ÉÇϸç, ÀÚµ¿À¸·Î (4.01 / 7.01 / 10.01)¼³Á¤ÀÌ µÇ¾îÀÖ½À´Ï´Ù.
1 point º¸Á¤ ½Ã, HANNA Quick CAL º¸Á¤ ¿ë¾×À» »ç¿ëÇÏ¿© º¸Á¤ÀÌ °¡´ÉÇÕ´Ï´Ù. pH ¿Í ECÀÇ º¸Á¤ÀÌ ¿Ï·áµÇ¸é,
È­¸é¿¡ ¡°CAL OK¡± °¡ È­¸é¿¡ ³ªÅ¸³³´Ï´Ù.

MODEL
HI 98131
pH
¹üÀ§
0.00~14.00pH
ÃÖ¼ÒÃøÁ¤´ÜÀ§
0.01pH
Á¤È®µµ ¡¾0.1pH
º¸Á¤
automatic,
at one or two points using standard buffers (pH 4.01, 7.01,10.01);
one point calibration using quick calibration solution
EC
¹üÀ§
0.00~6.00§Â/§¯
ÃÖ¼ÒÃøÁ¤´ÜÀ§
0.01§Â/§¯
Á¤È®µµ
¡¾2% F.S.
TDS ¹üÀ§ 0 ~ 3000 ppm (500 CF); 0 to 3999 ppm (700 CF)
ÃÖ¼ÒÃøÁ¤´ÜÀ§ 10 ppm (mg/L)
Á¤È®µµ ¡¾2% F.S.
¿Âµµ ¹üÀ§ 0.0 ~ 60.0¡ÆC / 32.0 ~ 140.0¡ÆF
ÃÖ¼ÒÃøÁ¤´ÜÀ§ 0.1¡ÆC / 0.1¡ÆF
Á¤È®µµ ¡¾0.5¡ÆC /¡¾1¡ÆF
¿Âµµ º¸»ó pH: automatic; EC/TDS: automatic with ¥â set at 1.9%/¡ÆC
±âŸ»ç¾ç EC/TDSº¸Á¤ automatic, one-point at 1.41 mS/cm or 5.00 mS/cm;
one point calibration using quick calibration solution
¿Âµµº¸»ó 0.0 to 50.0¡ÆC; 32.0 to 122.0¡ÆF; 237.1 to 323.1 K
TDSÀüȯ°è¼ö 0.5 (500 ppm) or 0.7 (700 ppm)
¹èÅ͸®Å¸ÀÔ/¼ö¸í 1.5V (4) / ¾à 100 ½Ã°£, 8ºÐÈÄ ÀÚµ¿ ²¨Áü
ÀÚµ¿ ²¨Áü 8ºÐ, 60ºÐ ÈÄ
ȯ°æ 0 to 50¡ÆC (32 to 122¡ÆF); RH max 100%
±Ô°Ý 163 x 40 x 26 mm (6.4 x 1.6 x 1.0'')
¹«°Ô 100 g (3.5 oz.)
ÁÖ¹®Á¤º¸

HI 98131,, HI 73128(Àü±Ø), HI 73128(electrode removal tool), ¹èÅ͸®, ¸Å´º¾ó